

- #MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SKIN#
- #MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SOFTWARE UPGRADE#
- #MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SOFTWARE#
Program terms and conditions are subject to change at any time and without notice.Restrictions and medical necessity requirements may apply. Coverage is contingent upon your health insurance medical policy guidelines. Insurance coverage and plan design varies and may impact the ability to upgrade.
#MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SOFTWARE#
The replacement warranty date of an insulin pump upgraded with the software will remain the same as the replacement warranty date of the initial pump purchased. All participants should consult their healthcare provider for all therapy related decisions.
#MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SOFTWARE UPGRADE#
We recommend you consult your healthcare provider regarding your eligibility to receive the software upgrade based on the labeling of the upgrade, which may differ from the labeling of the MiniMed™ 770G pump.
#MY INSURANCE WONT COVER ACCU CHEK TEST STRIPS SKIN#
The sensor is a small part of the continuous glucose monitoring system that is inserted just below the skin to measure glucose levels in interstitial fluid. It collects data measured by the sensor and wirelessly sends this data to monitoring devices. This device connects to a glucose sensor. Used with the sensor for continuous glucose monitoring (CGM). Medtronic Diabetes provides a variety of infusion sets to fit your patients' needs. Medtronic reservoir MMT-332A, 3.0 ml (300-unit) Replacement warranty could be up to 5 years for some insurance The weight of the pump is approximately 3 ounces. The pump dimensions in inches are approximately 2.1 width x 3.78 length x 0.96 depth. The pump also accepts an AA alkaline (LR6) or a fully charged AA NiMH (HR6) nickel-metal hydride rechargeable battery.Īt any time you can review 90 days of pump history. For best results, use a new AA lithium (FR6) battery. The pump requires one new AA (1.5 V) battery. Backlight time out 15 seconds (default), 30 seconds, one minute, three minutes.Rapid-acting U100 insulin (Humalog ® and NovoLog ®) that has been prescribed by a healthcare professional.Ġ to 35 units per hour or the Max Basal Rate amount, whichever is lower. Pump operating range is from 10.2 psiA (70.33 kPa) to 15.4 psiA (106.18 kPa).Air pressure range is from 700 hPa to 1060 hPa (10.2 psi to 15.4 psi). Pump storage temperature range is from -4☏ (-20☌) to 122☏ (50☌).

The MiniMed™ 770G insulin pump system is designed to withstand most conditions encountered in your daily life. CGM readings may not be transmitted from the CGM to the pump while in water.

The sensor and transmitter are water-resistant at 8 feet (2.4 meters) for up to 30 minutes. It is protected against the effects of being underwater to a depth of up to 12 feet (3.6 meters) for up to 24 hours. At the time of manufacture and when the reservoir and tubing are properly inserted, your pump is waterproof.
